CAM 70196

Computer-Assisted Navigation for Orthopedic Procedure

Category:Surgery   Last Reviewed:February 2019
Department(s):Medical Affairs   Next Review:February 2020
Original Date:February 2004    

Description
Computer-assisted navigation (CAN) in orthopedic procedures describes the use of computer-enabled tracking systems to facilitate alignment in a variety of surgical procedures, including fixation of fractures, ligament reconstruction, osteotomy, tumor resection, preparation of the bone for joint arthroplasty, and verification of the intended implant placement.

For individuals who are undergoing orthopedic surgery for trauma or fracture, ligament reconstruction, hip arthroplasty and periacetabular osteotomy, or total knee arthroplasty who receive CAN, the evidence includes randomized controlled trials (RCTs) and nonrandomized comparative studies. Relevant outcomes are symptoms, morbid events, and functional outcomes. Overall, the literature supports a decrease in variability of alignment with CAN, particularly with respect to the number of outliers. Although some observational data have suggested that malalignment may increase the probability of early failure, recent RCTs with short- to mid-term follow-up have not shown improved clinical outcomes with CAN. Given the low short-term revision rates associated with conventional procedures and the inadequate power of the available studies to detect changes in function using CAN, studies are needed that assess health outcomes using CAN in a larger number of subjects with longer follow-up to permit greater certainty on the impact of this technology. The evidence is insufficient to determine the effects of the procedure on health outcomes.

Background
IMPLANT ALIGNMENT FOR KNEE ARTHROPLASTY
For total knee arthroplasty, malalignment is commonly defined as a variation of more than 3° from the targeted position. Proper implant alignment is believed to be an important factor for minimizing long-term wear, the risk of osteolysis, and loosening of the prosthesis.

Navigation involves 3 steps: data acquisition, registration, and tracking.

Computer-Assisted Navigation
The goal of computer-assisted navigation (CAN) is to increase surgical accuracy and reduce the chance of malposition. 

In addition to reducing the risk of substantial malalignment, CAN may improve soft tissue balance and patellar tracking. CAN is also being investigated for surgical procedures with limited visibility such as placement of the acetabular cup in total hip arthroplasty, resection of pelvic tumors, and minimally invasive orthopedic procedures. Other potential uses of CAN for surgical procedures of the appendicular skeleton include screw placement for fixation of femoral neck fractures, high tibial osteotomy, and tunnel alignment during the reconstruction of the anterior cruciate ligament. 

CAN devices may be image-based or non-image-based. Image-based devices use preoperative computed tomography scans and operative fluoroscopy to direct implant positioning. Newer non-image-based devices use information obtained in the operating room, typically with infrared probes. For total knee arthroplasty, specific anatomic reference points are made by fixing signaling transducers with pins into the femur and tibia. Signal-emitting cameras (eg, infrared) detect the reflected signals and transmit the data to a dedicated computer. During the surgery, multiple surface points are taken from the distal femoral surfaces, tibial plateaus, and medial and lateral epicondyles. The femoral head center is typically calculated by kinematic methods that involve the movement of the thigh through a series of circular arcs, with the computer producing a 3-dimensional model that includes the mechanical, transepicondylar, and tibial rotational axes. CAN systems direct the positioning of the cutting blocks and placement of the prosthetic implants based on the digitized surface points and model of the bones in space. The accuracy of each step of the operation (cutting block placement, saw cut accuracy, seating of the implants) can be verified, thereby allowing adjustments to be made during surgery.

Navigation involves 3 steps: data acquisition, registration, and tracking.

Data Acquisition
Data can be acquired in 3 ways: fluoroscopically, guided by CT scan or magnetic resonance imaging (MRI), or guided by imageless systems. These data are then used for registration and tracking.

Registration
Registration refers to the ability to relate images (ie, radiographs, computed tomography scans, magnetic resonance imaging, or patients’ 3D anatomy) to the anatomic position in the surgical field. Registration techniques may require the placement of pins or “fiduciary markers” in the target bone. A surface-matching technique can also be used in which the shapes of the bone surface model generated from preoperative images are matched to surface data points collected during surgery.

Tracking
Tracking refers to the sensors and measurement devices that can provide feedback during surgery regarding the orientation and relative position of tools to bone anatomy. For example, optical or electromagnetic trackers can be attached to regular surgical tools, which then provide real-time information of the position and orientation of tool alignment concerning the bony anatomy of interest. 

VERASENSE (OrthoSense) is a single-use device that replaces the standard plastic tibial trial spacer used in total knee arthroplasty. The device contains microprocessor sensors that quantify load and contact position of the femur on the tibia after resections have been made. The wireless sensors send the data to a graphic user interface that depicts the load. The device is intended to provide quantitative data on the alignment of the implant and soft tissue balancing in place of intraoperative “feel.”

iASSIST (Zimmer) is an accelerometer-based alignment system with a user interface built into disposable electronic pods that attach onto the femoral and tibial alignment and resection guides. For the tibia, the alignment guide is fixed between the tibial spines and a claw on the malleoli. The relation between the electronic pod of the digitizer and the bone reference is registered by moving the limb into abduction, adduction, and neutral position. Once the information has been registered, the digitizer is removed and the registration data are transferred to the electronic pod on the cutting guide. The cutting guide can be adjusted for varus/valgus alignment and tibial slope. A similar process is used for the femur. The pods use wireless exchange of data and display the alignment information to the surgeon within the surgical field. A computer controller must also be present in the operating room.

Due to the lack of any recent studies on pelvic tumor resection, these sections of the Rationale were removed from this evidence review in 2016.

Regulatory Status
Because CAN is a surgical information system in which the surgeon is only acting on the information that is provided by the navigation system, surgical navigation systems generally are subject only to 510(k) clearance from FDA. As such, FDA does not require data documenting the intermediate or final health outcomes associated with CAN. (In contrast, robotic procedures, in which the actual surgery is robotically performed, are subject to the more rigorous requirement of the premarket approval application process.)

A variety of surgical navigation procedures have received FDA clearance through the 510(k) process with broad labeled indications. The following is an example; "The OEC FluoroTrak 9800 Plus provides the physician with fluoroscopic imaging during diagnostic, surgical and interventional procedures. The surgical navigation feature is intended as an aid to the surgeon for locating anatomical structures anywhere on the human body during either open or percutaneous procedures. It is indicated for any medical condition that may benefit from the use of stereotactic surgery and which provides a reference to rigid anatomical structures such as sinus, skull, long bone or vertebra visible on fluoroscopic images." FDA product code: haw.

Several navigation systems (eg, PiGalileo™ Computer-Assisted Orthopedic Surgery System, PLUS Orthopedics; OrthoPilot® Navigation System, Braun; Navitrack® Navigation System, ORTHOsoft) have received FDA clearance specifically for TKA. FDA-cleared indications for the PiGalileo system are representative. This system "is intended to be used in computer-assisted orthopedic surgery to aid the surgeon with bone cuts and implant positioning during joint replacement. It provides information to the surgeon that is used to place surgical instruments during surgery using anatomical landmarks and other data specifically obtained intra-operatively (eg, ligament tension, limb alignment). Examples of some surgical procedures include but are not limited to:

  • Total knee replacement supporting both bone referencing and ligament balancing techniques
  • Minimally invasive total knee replacement."

In 2013, the VERASENSE™Knee System from OrthoSensor™and the iAssist™Knee from Zimmer received 510(k) clearance from FDA.

Policy:
The use of computer assisted navigation for orthopedic procedures of the pelvis and appendicular skeleton is a technique that is integral to the primary surgery being performed and, therefore, not eligible for separate reimbursement. When billed, there will be no separate or additional payment for charges associated with computer assistance technology. Reimbursement will be based on the payment for the standard surgical procedure(s).

Examples of charges that are not eligible for separate or additional reimbursement are listed below: 

  • Increased operating room unit cost charges for the use of the computer assisted technology.
  • Charges billed under CPT or HCPCS codes that are specific to robotic assisted surgery, including , but not limited to, 20985, 0054T & 0055T.
  • Providers should NOT utilize Modifier 22 Increased Procedural Service to indicate computer assistance as this modifier should only be used to report unusual complications or complexities which occurred during the surgical procedure that are unrelated to the use of a robotic assistance system and must be supported by documentation.

Policy Guidelines 
The coding for this navigation includes 1 category I CPT code and 2 category III CPT codes:

20985: Computer-assisted surgical navigational procedure for musculoskeletal procedures; image-less (List separately in addition to code for primary procedure)
0054T: Computer-assisted musculoskeletal surgical navigational orthopedic procedure, with image guidance based on fluoroscopic images (List separately in addition to code for primary procedure)
0055T: Computer-assisted musculoskeletal surgical navigational orthopedic procedure, with image guidance based on CT/MRI images (List separately in addition to code for primary procedure)

All of the codes are intended to be used in addition to the code for the primary procedure.

A CPT category III add-on code was created for use of the VERASENSE™ system:

0396T Intra-operative use of kinetic balance sensor for implant stability during knee replacement arthroplasty (List separately in addition to code for primary procedure). 

Benefit Application
BlueCard/National Account Issues
State or federal mandates (e.g.,FEP) may dictate that all devices approved by the U.S. Food and Drug Administration (FDA) may not be considered investigational. Therefore, FDA-approved devices may only be assessed on the basis of their medical necessity.

Rationale 
This evidence review was originally created in February 2004 and has been updated regularly using the MEDLINE database. The most recent literature review was performed through February 5, 2018.

Evidence reviews assess the clinical evidence to determine whether the use of a technology improves the net health outcome. Broadly defined, health outcomes are length of life, quality of life, and ability to function---including benefits and harms. Every clinical condition has specific outcomes that are important to patients and to managing the course of that condition. Validated outcome measures are necessary to ascertain whether a condition improves or worsens; and whether the magnitude of that change is clinically significant. The net health outcome is a balance of benefits and harms.

To assess whether the evidence is sufficient to draw conclusions about the net health outcome of a technology, 2 domains are examined: the relevance and the quality and credibility. To be relevant, studies must represent one or more intended clinical uses of the technology in the intended population and compare an effective and appropriate alternative at a comparable intensity. For some conditions, the alternative will be supportive care or surveillance. The quality and credibility of the evidence depend on study design and conduct, minimizing bias and confounding that can generate incorrect findings. The randomized controlled trial (RCT) is preferred to assess efficacy; however, in some circumstances, nonrandomized studies may be adequate. RCTs are rarely large enough or long enough to capture less common adverse events and long-term effects. Other types of studies can be used for these purposes and to assess generalizability to broader clinical populations and settings of clinical practice.

For many orthopedic surgical procedures, optimal alignment is considered an important aspect of long-term success. For example, misplaced tunnels in the anterior cruciate ligament (ACL) or posterior cruciate ligament (PCL) reconstruction or malalignment of arthroplasty components are some of the leading causes of instability and reoperation. In total hip arthroplasty (THA), the orientation of the acetabular component of the THA is considered critical, while for total knee arthroplasty (TKA), alignment of the femoral and tibial components and ligament balancing are considered important outcomes. Ideally, one would prefer controlled trials comparing the long-term outcomes, including stability and reoperation rates.

TRAUMA OR FRACTURE
Computer-assisted surgery has been described as an adjunct to pelvic, acetabular, or femoral fractures. For example, fixation of these fractures typically requires percutaneous placement of screws or guidewires. Conventional fluoroscopic guidance (ie, C-arm fluoroscopy) provides imaging in only 1 plane. Therefore, the surgeon must position the implant in 1 plane and then get additional images in other planes in a trial-and-error fashion to ensure that the device has been properly placed. This process adds significant time in the operating room and radiation exposure. Computer-assisted surgery may permit minimally invasive fixation and provide more versatile screw trajectories with less radiation exposure. Therefore, computed-assisted surgery is considered an alternative to the existing image guidance using C-arm fluoroscopy.

Ideally, investigators would conduct controlled trials comparing operating room time, radiation exposure, and long-term outcomes of those whose surgery was conventionally guided using C-arm vs image-guided using computer-assisted surgery. While several in vitro and review studies had been published,1-3 when this evidence review was created in 2004, only a single clinical trial of computer-assisted surgery in trauma or fracture cases was identified.4 Computer-assisted navigation (CAN) for internal fixation of femoral neck fractures was retrospectively analyzed in 2 cohorts of consecutive patients (20 each, performed from 2001 to 2003 at 2 different campuses of a medical center) who underwent internal fixation with 3 screws for a femoral neck fracture.5 Three of 5 measurements of parallelism and neck coverage were significantly improved by CAN; they included a larger relative neck area held by the screws (32% vs 23%) and less deviation on the lateral projection for both the shaft (1.7° vs 5.2°) and the fracture (1.7° vs 5.5°) screw angles, all respectively. Slight improvements in anteroposterior screw angles (1.3° vs 2.1° and 1.3° vs 2.4°, respectively) were not statistically significant. There were 2 reoperations in the CAN group and 6 in the conventional group. Complications (collapse, subtrochanteric fracture, head penetration, osteonecrosis) were lower in the CAN group (3 vs 11, respectively).

Section Summary: Trauma or Fracture
There is limited literature on the use of CAN for trauma or fractures. Additional controlled studies that measure health outcomes are needed to evaluate this technology.

ANTERIOR OR POSTERIOR CRUCIATE LIGAMENT RECONSTRUCTION
A Cochrane review (2014) compared the effects of CAN with conventional operating techniques for ACL or PCL reconstruction.6 Five RCTs (total N=366 participants) on ACL reconstruction were included in the updated review; no studies involved PCL reconstruction. The quality of evidence ranged from moderate to very low. Pooled data showed no statistically or clinically relevant differences in self-reported health outcomes (International Knee Documentation Committee subjective scores and Lysholm Knee Scale scores) at 2 or more years of follow-up. No significant differences were found for secondary outcomes, including knee stability, range of motion, and tunnel placement. Overall, there was insufficient evidence to advise for or against the use of CAN. Four of the 5 trials included in the Cochrane review are described next.

Plaweski et al (2006) reported on a trial that randomized 60 patients to manual or computer-assisted guidance for tunnel placement with follow-up at 1, 3, 6, 12, 18, and 24 months.7 There were no differences between groups in measurements of laxity. However, there was less variability in side-to-side anterior laxity in the navigated group (eg, 97% were within 2 mm of laxity in the navigated group vs 83% in the conventional group at an applied force of 150 N). There was a significant difference in the sagittal position of the tibial tunnel (distance from the Blumensaat line, 0.4 mm vs -1.2 mm, respectively), suggesting possible impingement in extension for the conventional group. At the final follow-up (24 months), all knees had normal function, with no differences observed between groups.

Hart et al (2008) compared biomechanical radiographic with functional results in 80 patients randomized to ACL reconstruction using CAN (n=40) or to the standard manual targeting technique (n=40).8 The blinded evaluation found more exact bone tunnel placement with CAN, but no overall difference in biomechanical stability or function between groups.

Other studies have found no significant improvement in the accuracy of tunnel placement when using CAN. Meuffels et al (2012) reported on a double-blind controlled trial that randomized 100 patients to conventional or computer-assisted surgery.9 Evaluation by 3-dimensional computed tomography (CT) found no significant difference between groups for the accuracy or the precision of the femoral and tibial tunnel placement.

Mauch et al (2007) reported on a trial that randomized 53 patients to manual or computer-assisted ACL reconstruction by 3 experienced surgeons.10 Tunnel placement and range variance did not differ between groups, suggesting that experienced surgeons can achieve the same positioning as CAN.

Section Summary: Anterior or Posterior Cruciate Ligament Reconstruction
The evidence on CAN for ACL or PCL reconstruction includes a systematic review of 5 RCTs. These RCTs, of moderate to low quality, did not consistently demonstrated more accurate tunnel placement with CAN. No studies have shown an improvement in functional outcomes or need for revision when CAN is used for ACL or PCL reconstruction.

HIP ARTHROPLASTY AND PERIACETABULAR OSTEOTOMY
Few RCTs have evaluated CAN for hip procedures.

Total Hip Arthroplasty  
Parratte and Argenson (2007) randomized patients to CAN (n=30) or freehand cup positioning (n=30) for THA by an experienced surgeon.11 The mean additional time for the computer-assisted procedure was 12 minutes. There was no difference between the computer-assisted group and the freehand-placement group with regard to the mean abduction or anteversion angles measured by CT. A smaller variation in the positioning of the acetabular component was observed in the CAN group; 20% of cup placements were considered to be outliers in the CAN group compared with 57% in the freehand-placement group. In a randomized trial of 125 patients, Lass et al (2014) compared the acetabular component position for CAN and the conventional freehand technique.12 CT scans identified higher accuracy for acetabular component anteversion, less deviation from the target position for anteversion, and fewer outliers from the target for inclination and anteversion. Surgical time was 18 minutes longer for CAN. Functional outcomes were not assessed.

A study by Manzotti et al (2011) compared leg length restoration in a matched-pair study.13 Forty-eight patients undergoing THA with CAN were compared with patients who were matched for age, sex, arthritis level, preoperative diagnosis, and preoperative leg length discrepancy and underwent conventional freehand THA using the same implant in the same period. The mean preoperative leg length discrepancy was 12.17 mm in the CAN group and 11.94 mm in the standard group. Surgical time was increased by 16 minutes in the CAN group (89 minutes vs 73 minutes). There was a significant decrease in both the mean postoperative leg length discrepancy (5.06 mm vs 7.65 mm) and the number of cases with a leg length discrepancy of 10 mm or more (5 patients vs 13 patients), all respectively. Outcomes at 40-month follow-up (range, 7-77 months) did not differ significantly for the Harris Hip Score (88.87 vs 89.73) or the 100-point normalized Western Ontario and McMaster Universities Arthritis Index score (9.33 vs 13.21; p=0.050), all respectively. Longer follow-up with a larger number of subjects is needed to determine whether CAN influences clinical outcomes.

Minimally Invasive THA
It has been proposed that CAN might overcome the difficulties of reduced visibility of the surgical area associated with minimally invasive procedures. A review by Ulrich et al (2007) summarized studies that compared outcomes from minimally invasive THA using CAN with standard THA.14 Seventeen studies were described in this evidence-based review, including 9 prospective comparisons, 7 retrospective comparisons, and 1 large (N=100) case series. Reviewers concluded that alignment with minimally invasive CAN appears to be at least as good as standard THA, although the more consistent alignment must be balanced against the expense of the computer systems and increased surgical time.

Short-term outcomes of minimally invasive THA approach with CAN (n=35) compared with conventional posterolateral THA (n=40) was reported by Reininga et al (2013).15 This randomized comparison found no group differences in the recovery of gait at up to 6 months postsurgery.

Periacetabular Osteotomy
In a trial by Hsieh et al (2006), 36 patients with symptomatic adult dysplastic hip were randomized to CT-based navigation or the conventional technique for periacetabular osteotomy.16 An average of 0.6 intraoperative radiographs were taken in the navigated group compared with 4.4 in the conventional group, resulting in a total surgical time that was 21 minutes shorter for CAN. There were no differences between groups for correction in femoral head coverage or functional outcomes (pain, walking, range of motion) at 24 months.

Total Hip Resurfacing
Stiehler et al (2013) reported on short-term radiographic and functional outcomes from a randomized comparative trial of THR using CAN and conventional THR in 75 patients.17 For most of the radiographic measures, there were no significant differences between the CAN and conventional THR groups. There were fewer outliers (≥5°) for the femoral component with CAN (11%) compared with conventional placement (32%). At 6-month follow-up, there were no differences between groups in the final Western Ontario and McMaster Universities score or Harris Hip Score. The CAN group did show a greater percentage improvement in the Western Ontario and McMaster Universities scores and Harris Hip Score due to differences between groups at baseline.

Section Summary: Hip Arthroplasty and Periacetabular Osteotomy
Relatively few RCTs have evaluated CAN for hip procedures. Although there was early interest in this technology, no recent RCTs have been identified. There is inconsistent evidence from these small trials on whether CAN improves alignment with conventional or minimally invasive THA. One RCT found improved alignment when CAN was used for hip resurfacing, but there was little evidence of improved outcomes at short-t erm follow-up. Overall, improved health outcomes have not been demonstrated with CAN for any hip procedures.

TOTAL KNEE ARTHROPLASTY
Alignment of a knee prosthesis can be measured along several different axes, including the mechanical axis, and the frontal and sagittal axes of both the femur and tibia.

Systematic Reviews
TEC Assessment (2007) evaluated CAN for TKA.18 Nine studies from 7 RCTs were reviewed. Selection criteria for the RCTs included having at least 25 patients per group and comparing limb alignment and surgical or functional outcomes following TKA with CAN or conventional methods. Also reviewed were cohort and case series that evaluated long-term associations between malalignment of prosthetic components and poor outcomes. In the largest of the cohort studies, which included more than 2000 patients (3000 knees) with an average of 5-year follow-up, 41 revisions for tibial component failure (1.3% of the cohort) were identified. The relative risk for age was estimated at 8.3, with a greater risk observed in younger, more active patients. For malalignment (defined as >3° varus or valgus), the relative risk was estimated to be 17.3.

Pooled data from the prospective RCTs showed: 

  • significant decrease in the percentage of limbs considered to be outliers (eg, >3° of varus or valgus from a neutral mechanical axis) with CAN.
  • Surgical time increased by 10 to 20 minutes in all but 1 study. CAN-associated reduction in blood loss was less consistent, with only some of the studies showing a decrease in blood loss of 100 to 200 mL.
  • RCTs that assessed function (up to 2 years of follow-up) did not find evidence of improved health outcomes. However, the studies were not adequately powered to detect functional differences, and data on long-term follow-up were not available.

Based on the deficiencies in the available evidence (eg, potential for bias in observational studies, lack of long-term follow-up in the RCTs), TEC reviewers concluded that it was not possible to determine whether the degree of improvement in alignment reported in the RCTs led to meaningful improvements in clinically relevant outcomes such as pain, function, or revision surgery.

A meta-analysis by Xie et al (2012) included 21 randomized trials (total N=2658 patients) that reported on clinical outcomes with or without the use of CAN.19 Most trials included in the review had short-term follow-up. As was found in the 2007 TEC Assessment, surgical time was significantly increased with CAN for TKA, but there was no significant difference between approaches in total operative blood loss, the Knee Society Score (KSS), or range of motion. Rebal et al (2014) conducted a meta-analysis of 20 RCTs (total N=1713 knees) that compared imageless navigation technology with conventional manual guides.20 Nine studies were considered to have a low risk of bias due to the blinding of patients or surgical personnel. Fifteen studies were considered to have a low risk of bias due to evaluator blinding. The improvement in KSS was statistically superior in the CAN group at 3 months (4 studies; 68.5 vs 58.1, p=0.03) and 12 to 32 months (5 studies; 53.1 vs 45.8, p<0.01). However, these improvements did not achieve the minimal clinically significant difference, defined as a change of 34.5 points.

More recent studies (2014, 2015) have also found longer surgical times and few differences in clinical outcome measures at 1-year follow-up.21,22

Effect of CAN on Mid- to Long-Term Outcomes
Most studies comparing outcomes at mid- to long-term generally have shown a reduction in the number of outliers with CAN, but little to no functional difference between the CAN and conventional TKA groups.

Follow-up from 4 randomized trials was published between 2013 and 2016; they assessed mid-term functional outcomes following CAN for TKA. Blakeney et al (2014) reported on 46-month follow-up for 107 patients from a randomized trial of CAN vs conventional surgery.23 There was a trend toward higher scores on the Oxford Knee Questionnaire with CAN, with a mean score of 40.6 for the CAN group compared with 37.6 and 36.8 in extramedullary and intramedullary control groups. There were no significant differences in the 12-Item Short-Form Health Survey Physical Component or Mental Component Summary scores. The trial was underpowered, and the clinical significance of this trend for the Oxford Knee Questionnaire is unclear.

Lutzner et al (2013) reported on 5-year follow-up for 67 of 80 patients randomized to CAN or conventional TKA.24 There was a significant decrease in the number of outliers with CAN (3 vs 9, p=0.048), but no significant differences between groups on the KSS or EuroQoL questionnaire for quality of life. Cip et al (2014) found a significant decrease in malalignment with CAN, but no significant differences in implant survival or consistent differences clinical outcome measures between the navigated (n=100) and conventional (n=100) TKA groups at minimum 5-year follow-up.25 Song et al (2016) also reported on a reduction in the number of outliers with CAN (7.3% vs 20%, p=0.006), with no significant differences in clinical outcomes at 8-year follow-up.26 The trial, which assessed 80 patients (88 knees) was powered to detect a 3-point difference in KSS results.

Other comparative study designs have found no significant differences in clinical outcomes following CAN. In a comparative study by Kim et al (2009), which assessed 160 bilateral TKAs performed by experienced surgeons in Asia, differences in alignment measures between the conventionally prepared knee and the knee prepared with CAN assistance were minimal.27 In 2012, this group reported longer term follow-up (mean, 10.8 years) on 520 patients who underwent CAN for 1 knee and conventional TKA for the other knee (randomized).28 There were no significant differences between groups for knee function or pain measures. Kaplan-Meier survivorship at 10.8 years was 98.8% in the CAN knee and 99.2% for the conventional knee. Two additional nonrandomized comparative studies (2012, 2013) found an improvement in alignment with CAN, but no difference in clinical or functional outcomes at 5-year follow-up compared with conventional TKA.29,30

Hoffart et al (2012) used an alternate allocation design with 195 patients to compare functional outcomes following CAN-assisted TKA with conventional instrumentation.31 An independent observer performed the pre- and postoperative assessments. After 5 years, complete clinical scores were only available for 121 (62%) patients. There was no significant difference in the frequency of malalignment between groups. The CAN group had a better mean KSS as well as mean function and knee scores. Mean pain scores did not differ between groups. Study limitations included the high loss to follow-up and lack of subject blinding.

Dyrhovden et al (2016) assessed survivorship and the relative risk of revision at 8-year follow-up for 23,684 cases from the Norwegian Arthroplasty Register for patients treated with CAN or conventional surgery.32 Overall prosthesis survival and risk of revision were similar for both groups, although revisions due to malalignment were reduced with CAN (relative risk, 0.5; 95% confidence interval, 0.3 to 0.9; p=0.02). There were no significant differences between groups for other reasons for revision (eg, aseptic loosening, instability, periprosthetic fracture, decreased range of motion). At 8 years, the survival rate was 94.8% (95% confidence interval, 93.8% to 95.8%) in the CAN group and 94.9% (95% confidence interval, 94.5% to 95.3%) for conventional surgery.

Section Summary: Total Knee Arthroplasty
A large number of RCTs have assessed outcomes for TKA using CAN or conventional TKA without CAN. Results are consistent in showing reductions in the proportion of outliers greater than 3° in alignment. Results up to 10 years postoperatively have not shown that these differences in alignment lead to improved patient outcomes.

SUMMARY OF EVIDENCE
For individuals who are undergoing orthopedic surgery for trauma or fracture, ligament reconstruction, hip arthroplasty and periacetabular osteotomy, or TKA who receive CAN, the evidence includes randomized controlled trials and nonrandomized comparative studies. Relevant outcomes are symptoms, morbid events, and functional outcomes. Overall, the literature supports a decrease in the variability of alignment with CAN, particularly with respect to the number of outliers. Although some observational data have suggested that malalignment may increase the probability of early failure, recent randomized controlled trials with short-to mid-term follow-up have not shown improved clinical outcomes with CAN. Given the low short-term revision rates associated with conventional procedures and the inadequate power of the available studies to detect changes in function using CAN, studies are needed that assess health outcomes using CAN in a larger number of subjects with longer follow-up to permit greater certainty on the impact of this technology. The evidence is insufficient to determine the effects of the procedure on health outcomes.

CLINICAL INPUT FROM PHYSICIAN SPECIALTY SOCIETIES AND ACADEMIC MEDICAL CENTERS
While the various physician specialty societies and academic medical centers may collaborate with and make recommendations during this process, through the provision of appropriate reviewers, input received does not represent an endorsement or position statement by the physician specialty societies or academic medical centers, unless otherwise noted.

In response to requests, input was received from 3 academic medical centers while this policy was under review in 2011. Input was mixed on whether computer-assisted navigation is considered investigational. One reviewer provided additional references on high tibial osteotomy and pelvic tumor resection.

PRACTICE GUIDELINES AND POSITION STATEMENTS
No guidelines or statements were identified.

U.S. PREVENTIVE SERVICES TASK FORCE RECOMMENDATIONS
Not applicable. 

ONGOING AND UNPUBLISHED CLINICAL TRIALS
One currently unpublished trial that might influence this review is listed in Table 1.

Table 1. Summary of Key Trials

NCT No. Trial Name Planned Enrollment Completion Date

Unpublished

NCT01469299a

Prospective Study Measuring Clinical Outcomes of Knee Arthroplasty Using the VERASENSE™ Knee System

285 Dec 2016 (completed)

NCT: national clinical trial.
a Denotes industry-sponsored or cosponsored trial.

References: 

  1. Hofstetter R, Slomczykowski M, Krettek C, et al. Computer-assisted fluoroscopy-based reduction of femoral fractures and antetorsion correction. Comput Aided Surg. 2000;5(5):311-325. PMID 11169877
  2. Schep NW, Broeders IA, van der Werken C. Computer assisted orthopaedic and trauma surgery. State of the art and future perspectives. Injury. May 2003;34(4):299-306. PMID 12667784
  3. Slomczykowski MA, Hofstetter R, Sati M, et al. Novel computer-assisted fluoroscopy system for intraoperative guidance: feasibility study for distal locking of femoral nails. J Orthop Trauma. Feb 2001;15(2):122-131. PMID 11232651
  4. Suhm N, Jacob AL, Nolte LP, et al. Surgical navigation based on fluoroscopy--clinical application for computer-assisted distal locking of intramedullary implants. Comput Aided Surg. 2000;5(6):391-400. PMID 11295852
  5. Liebergall M, Ben-David D, Weil Y, et al. Computerized navigation for the internal fixation of femoral neck fractures. J Bone Joint Surg Am. Aug 2006;88(8):1748-1754. PMID 16882897
  6. Eggerding V, Reijman M, Scholten RJ, et al. Computer-assisted surgery for knee ligament reconstruction. Cochrane Database Syst Rev. 2014;8:CD007601. PMID 25088229
  7. Plaweski S, Cazal J, Rosell P, et al. Anterior cruciate ligament reconstruction using navigation: a comparative study on 60 patients. Am J Sports Med. Apr 2006;34(4):542-552. PMID 16556753 
  8. Hart R, Krejzla J, Svab P, et al. Outcomes after conventional versus computer-navigated anterior cruciate ligament reconstruction. Arthroscopy. May 2008;24(5):569-578. PMID 18442690
  9. Meuffels DE, Reijman M, Verhaar JA. Computer-assisted surgery is not more accurate or precise than conventional arthroscopic ACL reconstruction: a prospective randomized clinical trial. J Bone Joint Surg Am. Sep 5 2012;94(17):1538-1545. PMID 22832975
  10. Mauch F, Apic G, Becker U, et al. Differences in the placement of the tibial tunnel during reconstruction of the anterior cruciate ligament with and without computer-assisted navigation. Am J Sports Med. Nov 2007;35(11):1824-1832. PMID 17878429
  11. Parratte S, Argenson JN. Validation and usefulness of a computer-assisted cup-positioning system in total hip arthroplasty. A prospective, randomized, controlled study. J Bone Joint Surg Am. Mar 2007;89(3):494-499. PMID 17332097
  12. Lass R, Kubista B, Olischar B, et al. Total hip arthroplasty using imageless computer-assisted hip navigation: a prospective randomized study. J Arthroplasty. Apr 2014;29(4):786-791. PMID 24290738
  13. Manzotti A, Cerveri P, De Momi E, et al. Does computer-assisted surgery benefit leg length restoration in total hip replacement? Navigation versus conventional freehand. Int Orthop. Jan 2011;35(1):19-24. PMID 19904533
  14. Ulrich SD, Bonutti PM, Seyler TM, et al. Outcomes-based evaluations supporting computer-assisted surgery and minimally invasive surgery for total hip arthroplasty. Expert Rev Med Devices. Nov 2007;4(6):873-883. PMID 18035952
  15. Reininga IH, Stevens M, Wagenmakers R, et al. Comparison of gait in patients following a computer-navigated minimally invasive anterior approach and a conventional posterolateral approach for total hip arthroplasty: a randomized controlled trial. J Orthop Res. Feb 2013;31(2):288-294. PMID 22886805
  16. Hsieh PH, Chang YH, Shih CH. Image-guided periacetabular osteotomy: computer-assisted navigation compared with the conventional technique: a randomized study of 36 patients followed for 2 years. Acta Orthop. Aug 2006;77(4):591-597. PMID 16929435
  17. Stiehler M, Goronzy J, Hartmann A, et al. The First SICOT Oral Presentation Award 2011: imageless computer-assisted femoral component positioning in hip resurfacing: a prospective randomised trial. Int Orthop. Apr 2013;37(4):569-581. PMID 23385606
  18. Blue Cross and Blue Shield Association Technology Evaluation Center. Computer-assisted navigation for total knee arthroplasty. Technology Assessment Feb 2007;Volume 22:Tab 10. PMID 18411501
  19. Xie C, Liu K, Xiao L, et al. Clinical outcomes after computer-assisted versus conventional total knee arthroplasty. Orthopedics. May 1 2012;35(5):e647-653. PMID 22588405
  20. Rebal BA, Babatunde OM, Lee JH, et al. Imageless computer navigation in total knee arthroplasty provides superior short term functional outcomes: a meta-analysis. J Arthroplasty. May 2014;29(5):938-944. PMID 24140274
  21. Gothesen O, Espehaug B, Havelin LI, et al. Functional outcome and alignment in computer-assisted and conventionally operated total knee replacements: a multicentre parallel-group randomised controlled trial. Bone Joint J. May 2014;96-B(5):609-618. PMID 24788494
  22. Blyth MJ, Smith JR, Anthony IC, et al. Electromagnetic navigation in total knee arthroplasty-a single center, randomized, single-blind study comparing the results with conventional techniques. J Arthroplasty. Feb 2015;30(2):199-205. PMID 25263246
  23. Blakeney WG, Khan RJ, Palmer JL. Functional outcomes following total knee arthroplasty: a randomised trial comparing computer-assisted surgery with conventional techniques. Knee. Mar 2014;21(2):364-368. PMID 24703685
  24. Lutzner J, Dexel J, Kirschner S. No difference between computer-assisted and conventional total knee arthroplasty: five-year results of a prospective randomised study. Knee Surg Sports Traumatol Arthrosc. Oct 2013;21(10):2241-2247. PMID 23851969
  25. Cip J, Widemschek M, Luegmair M, et al. Conventional versus computer-assisted technique for total knee arthroplasty: a minimum of 5-year follow-up of 200 patients in a prospective randomized comparative trial. J Arthroplasty. Sep 2014;29(9):1795-1802. PMID 24906519
  26. Song EK, Agrawal PR, Kim SK, et al. A randomized controlled clinical and radiological trial about outcomes of navigation-assisted TKA compared to conventional TKA: long-term follow-up. Knee Surg Sports Traumatol Arthrosc. Nov 2016;24(11):3381-3386. PMID 26831857
  27. Kim YH, Kim JS, Choi Y, et al. Computer-assisted surgical navigation does not improve the alignment and orientation of the components in total knee arthroplasty. J Bone Joint Surg Am. Jan 2009;91(1):14-19. PMID 19122074
  28. Kim YH, Park JW, Kim JS. Computer-navigated versus conventional total knee arthroplasty a prospective randomized trial. J Bone Joint Surg Am. Nov 21 2012;94(22):2017-2024. PMID 23052635
  29. Hoppe S, Mainzer JD, Frauchiger L, et al. More accurate component alignment in navigated total knee arthroplasty has no clinical benefit at 5-year follow-up. Acta Orthop. Dec 2012;83(6):629-633. PMID 23140107
  30. Yaffe M, Chan P, Goyal N, et al. Computer-assisted versus manual TKA: no difference in clinical or functional outcomes at 5-year follow-up. Orthopedics. May 1 2013;36(5):e627-632. PMID 23672916 
  31. Hoffart HE, Langenstein E, Vasak N. A prospective study comparing the functional outcome of computer-assisted and conventional total knee replacement. J Bone Joint Surg Br. Feb 2012;94(2):194-199. PMID 22323685
  32. Dyrhovden GS, Fenstad AM, Furnes O, et al. Survivorship and relative risk of revision in computer-navigated versus conventional total knee replacement at 8-year follow-up. Acta Orthop. Dec 2016;87(6):592-599. PMID 27775460

Coding Section

Codes  Number  Description 
 CPT 20985 

Computer-assisted surgical navigational procedure for musculoskeletal procedures; image-less (List separately in addition to code for primary procedure) 

  0054T Computer-assisted musculoskeletal surgical navigational orthopedic procedure, with image guidance based on fluoroscopic images (List separately in addition to code for primary procedure) 
  0055T Computer-assisted musculoskeletal surgical navigational orthopedic procedure with image guidance based on CT/MRI images (List separately in addition to code for primary procedure) 
  0396T  Intra-operative use of kinetic balance sensor for implant stability during knee replacement arthroplasty (List separately in addition to code for primary procedure) 
ICD-9 Diagnosis    Investigational for all codes 
ICD-10-CM (effective 10/01/15)    Investigational for all codes  
ICD-10-PCS (effective 10/01/15)  8E09XBZ Computer Assisted Procedure of Head and Neck Region
  8E0WXBZ  Computer Assisted Procedure of Trunk Region 
  8E0XXBZ  Computer Assisted Procedure of Upper Extremity 
  8E0YXBZ Computer Assisted Procedure of Lower Extremity 
  XR2G021  New Technology, Joints, Monitoring, Open, Intraoperative Knee 
  XR2H021 Replacement Sensor, Knee Codes  
Type of Service     
Place of Service     

Procedure and diagnosis codes on Medical Policy documents are included only as a general reference tool for each policy. They may not be all-inclusive.

This medical policy was developed through consideration of peer-reviewed medical literature generally recognized by the relevant medical community, U.S. FDA approval status, nationally accepted standards of medical practice and accepted standards of medical practice in this community, Blue Cross and Blue Shield Association technology assessment program (TEC) and other non-affiliated technology evaluation centers, reference to federal regulations, other plan medical policies and accredited national guidelines.

"Current Procedural Terminology© American Medical Association.  All Rights Reserved" 

History From 2014 Forward     

02/20/2019 

Annual review, no change to policy intent. Updating background, rationale and references 

03/05/2018 

Annual review, no change to policy intent. Updating guidelines and coding to include CPT 0396T. 

02/09/2017 

Updating policy to remove investigational status of this procedure and replace policy language with:The use of computer assistance for orthopedic procedures of the pelvis and appendicular skeleton is a technique that is integral to the primary surgery being performed and, therefore, not eligible for separate reimbursement. When billed, there will be no separate or additional payment for charges associated with computer assistance technology. Reimbursement will be based on the payment for the standard surgical procedure(s). 

02/08/2017 

Annual review, no change to policy intent. Updating title, background, description, rationale and references. 

02/09/2016 

Annual review, no change to policy intent. Updating background, description, rationale and references. 

02/12/2015 

Annual review, no change to policy intent. Updated background, regulatory status, rationale and references. Added guidelines and coding. 

02/10/2014

Annual Review. Updated background, rationale and references. No change to policy intent.


Go Back